Manual Gas Tight Syringes
Gas tight syringes for manual injections on GC instruments; includes fixed-needle, removable-needle formats in various sizes, needle gauges, needle point styles, and terminations; includes zero dead-volume and headspace syringes.
- (16)
- (10)
- (30)
- (7)
- (88)
- (21)
- (25)
- (1)
- (60)
- (6)
- (1)
- (2)
- (9)
- (1)
- (1)
- (2)
- (23)
- (1)
- (2)
- (43)
- (1)
- (8)
- (58)
- (42)
- (23)
- (5)
- (58)
- (7)
- (45)
- (3)
- (4)
- (5)
- (1)
- (3)
- (102)
- (16)
- (110)
- (1)
- (44)
- (12)
- (2)
- (2)
- (16)
- (7)
- (7)
- (39)
- (15)
- (39)
- (59)
- (1)
- (2)
- (13)
- (11)
- (1)
- (91)
- (10)
- (59)
- (23)
- (12)
- (14)
- (48)
- (10)
- (1)
- (3)
- (10)
- (23)
- (1)
- (1)
- (134)
- (11)
- (1)
- (4)
- (4)
- (214)
- (1)
- (8)
- (1)
- (8)
- (7)
- (301)
- (13)
- (10)
- (15)
- (6)
- (185)
- (1)
- (2)
- (14)
- (1)
- (2)
- (1)
- (2)
- (1)
- (4)
- (2)
- (24)
- (4)
- (12)
- (9)
- (2)
- (12)
- (11)
- (3)
- (9)
- (5)
- (2)
- (6)
- (2)
- (25)
- (1)
- (3)
- (17)
- (2)
- (1)
- (1)
- (2)
- (1)
- (8)
- (1)
- (7)
- (5)
Filtered Search Results
Hamilton™ 700 7000/1700 1000 Series Microliter™/Gastight™: LT Termination
Syringes have built-in Chaney Adapters
| Quantity | Ea. |
|---|---|
| Min. Temperature (English) | 50°F |
| Min. Temperature (Metric) | 10°C |
| Max. Pressure | 200 psi |
Hamilton™ 1700/1000 Series Gastight™ Instrument Syringes: DX Termination
Syringes are designed to fit into, or with, various different instruments such as the MICROLAB™ 500 and MICROLAB 1000
| Includes | Instrument plunger stop |
|---|---|
| Needle Point Number | No Needle Included |
| For Use With (Equipment) | Microlab 500 Diluters/Dispensers |
| Product Type | Gastight Syringe |
| Connection Type | Luer Lock |
| Max. Temperature (English) | 239°F |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip) |
| Max. Temperature (Metric) | 115°C |
| Autoclavable | Autoclavable |
Hamilton™ 1700 Series Gastight™ Gel Loading Syringes, 10uL
Syringes are designed to work for multiplex DNA sequencing applications
| Needle Point Number | 3 |
|---|---|
| Max. Temperature (English) | 122°F |
| Volume (Metric) | 10 μL |
| Min. Temperature (English) | 50°F |
| Max. Temperature (Metric) | 50°C |
| For Use With (Application) | Designed to work for multiplex DNA sequencing applications |
| Autoclavable | Not Autoclavable |
| Sterility | Sterile |
| Max. Pressure | 1000 psi |
Hamilton™ 1800 Series Gastight™ Fixed-Needle Syringes
Reinforced plunger version of the 1700 series syringes is ideal for dispensing volumes from 1 μL up to 500 μL.
| Needle Point Number | 2 |
|---|---|
| Quantity | 1/Pk. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 50°C |
| For Use With (Application) | Dispensing volumes from 1μL up to 500μL |
| Max. Pressure | 1000 psig (68.9 bar) |
| Product Type | Gastight, Cemented Needle |
| Connection Type | Cemented |
| Max. Temperature (English) | 122°F |
| Needle Point Style | 2 |
| Length (English) Needle | 2 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
Hamilton™ Microliter 700 Cemented Autosampler Syringes, Model 1701 N
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.
Hamilton™ 700/1700 Series Microliter™/Gastight™ On-Column Manual Injection Syringes
Syringes are designed to work with On-Column GC Injectors.
| Diameter (English) Inner | 0.019 in. |
|---|---|
| For Use With (Equipment) | On-Column GC Injectors |
| Product Type | Microliter Syringe |
| Diameter (Metric) Outer | 0.66 cm |
| Max. Temperature (English) | 239°F |
| Diameter (English) Outer | 0.26 in. |
| Volume (Metric) | 10 μL |
| Model | 701 |
| Diameter (Metric) Inner | 0.048 cm |
| Material | Stainless Steel, Borosilicate Glass, Fused Silica |
| Max. Temperature (Metric) | 115°C |
| Sterility | Sterile |
| Max. Pressure | 2000 psi |
| Needle Point Number | 2 |
|---|---|
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 50°C |
| For Use With (Application) | Ideal for despensing both liquids and gases |
| Product Type | Gastight Syringe |
| Diameter (Metric) Outer | 7.75 mm |
| Max. Temperature (English) | 122°F |
| Diameter (English) Outer | 0.305 in. |
| Needle Point Style | Sharp, Bevel, Curved, Non-coring |
| Diameter (Metric) Outer Needle | 0.72 mm |
| Length (English) Needle | 2 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Diameter (English) Outer Needle | 0.028 in. |
Hamilton™ 7000 Series Gastight™ and Microliter™ Digital Syringes: KH Termination
Easily achieves precision up to 0.5% while dispensing volumes from 500μL down to 50nL
| Length (Metric) | 70 mm |
|---|---|
| Length (English) | 2.75 in. |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | Analytical instrument calibration (AA/ICP, GC, HPLC) , prepare standards and spike samples, eliminates parallax errors by providing a digital readout on its integrated LCD screen and also used for pipetting and HPLC injections |
| Max. Pressure | 6000 psi |
| Diameter (Metric) Outer | 7.82 mm |
| Connection Type | Knurled Hub |
| Max. Temperature (English) | 239°F |
| Diameter (English) Outer | 0.3 in. |
| Length (English) Needle | 2.75 in. |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Diameter (English) Outer Needle | 0.02 in. |
Hamilton™ 700 7000/1700 1000 Series Microliter™/Gastight™: RN Termination
Syringes have built-in Chaney Adapters
Hamilton™ 1700 Series Gastight™ Syringes: Cemented Needle (N) Termination
Gastight version of the original 700 series syringes, ideal for dispensing volumes from 1 up to 500μL. ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal.
Hamilton™ 700/700 Microliter™: RN Termination
Syringes have a built-in syringe guide, designed to prevent the plunger from bending and pulling out of the syringe
Hamilton™ Gastight™ Valco VISF-1 HPLC Injection Valve Syringes
Designed for use in Valco VISF-1 HPLC injection valves. Hamilton Gastight Valco VISF-1 HPLC Injection Valve Syringes have PTFE plunger tips that create tight connection between syringe barrel and plunger allowing for liquid or gas sampling.
| Length (Metric) | 1.91 cm |
|---|---|
| For Use With (Equipment) | Valco VISF-1 HPLC Injection Valves |
| Product Type | Gastight Syringe |
| Max. Temperature (English) | 239°F |
| Length (English) | 0.75 in. |
| Needle Point Style | 3 |
| Quantity | 1 Pack |
| Diameter (Metric) Outer Needle | 0.072 cm |
| Material | Stainless Steel, Borosilicate Glass, PTFE |
| Certifications/Compliance | ISO 9001:2008, FDA |
| Max. Temperature (Metric) | 115°C |
| Autoclavable | Autoclavable |
| Diameter (English) Outer Needle | 0.0283 in. |
Hamilton™ 1700/1000 Series Gastight™ Instrument Syringes: CX Termination
Syringes are designed to fit into, or with, various different instruments such as the MICROLAB™ 500 and MICROLAB 1000
| Includes | Instrument plunger stop |
|---|---|
| Needle Point Number | No Needle Included |
| Product Type | Gastight Syringe |
| Diameter (Metric) Outer | 7.75 mm |
| Connection Type | ChemSeal |
| Max. Temperature (English) | 239°F |
| Diameter (English) Outer | 0.305 in. |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip) |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | For dispensing volumes from 100μL up to 100mL |
| Autoclavable | Autoclavable |
Hamilton™ Modified 7000 Microliter™ Syringes
This series of syringes is ideal for dispensing volumes from 0.05 μL up to 5 μL. The 7000 series is the only zero dead volume syringe. The fine gauge plunger wire travels to the tip of the needle ensuring that all solvent is expelled from the needle.